Hold the SET button for three seconds until "M0" flashes. Use the arrows to select a slot (M0–M9). Press OK to save your current settings to that slot.
Note that if the load voltage display is lower than the set output, this is often due to line drop (voltage loss over long or thin wires).
By long-pressing the button for 10 seconds, you can change the startup behaviors of the microcontroller:
Unlike older analog converters that rely on mechanical potentiometers (trim pots) for calibration—which can be fragile and prone to failure—the BST900W utilizes a fully digital control interface with a 1.3-inch four-digit seven-segment LED display and tactile buttons. This allows for precise, repeatable adjustments of voltage, current, and power with resolutions as fine as 0.01 Volts and 0.001 Amperes.
Are you encountering any specific on the display? bst900w manual
The input power supply cannot provide enough current, causing the input voltage to sag below the 8V cutoff limit. Alternatively, the module is overheating.
High-voltage DC power carries significant risks of electrical arcs and burns. Safety Guidelines
The BST900W is a high-power, digitally controlled step-up converter. In simple terms, it takes a direct current (DC) voltage ranging from 8 Volts to 60 Volts and "boosts" (elevates) it to a higher adjustable voltage output between 8.5 Volts and 120 Volts. It is built on a platform, which contributes to its high efficiency and reduced heat generation.
4-digit LED or LCD showing Volts (V), Amps (A), Watts (W), and Capacity (Ah) Cooling: Built-in fan for thermal management 🕹️ Basic Operation Guide Primary Controls SET Button: Toggles between setting voltage and current. Up/Down Arrows: Increases or decreases the selected value. OK Button: Turns the output ON or OFF . Indicators: OUT: Active output. CV: Constant Voltage mode. CC: Constant Current mode (active during current limiting). ⚙️ Advanced Programming Data Storage and Recall The device can store up to 10 groups of settings (0–9). Hold the SET button for three seconds until "M0" flashes
: Connect your load or battery pack to the OUT+ and OUT- terminals.
The BST900W features digital control logic to store presets and fine-tune output parameters. Basic Voltage and Current Configuration
Press and hold SET until unit beeps twice. Exit by turning off and on normally.
: Illuminates when the load draws enough current to hit your current limit, switching the module into a protective constant current mode. Button Functions Note that if the load voltage display is
Press and hold the button for 3 seconds until the display shows M-0 .
Press again to switch to the current setting, and adjust using the arrows. Press SET to exit the setup mode. Press OK to start the output. Setting Automatic/Manual Start
Shows real-time: